4.6 Article Proceedings Paper

Semi-physical parameter identification for an iron-loss formula allowing loss-separation

Journal

JOURNAL OF APPLIED PHYSICS
Volume 113, Issue 17, Pages -

Publisher

AMER INST PHYSICS
DOI: 10.1063/1.4795618

Keywords

-

Ask authors/readers for more resources

This paper presents a semi-physical parameter identification for a recently proposed enhanced iron-loss formula, the IEM-Formula. Measurements are performed on a standardized Epstein frame by the conventional field-metric method under sinusoidal magnetic flux densities up to high magnitudes and frequencies. Quasi-static losses are identified on the one hand by point-by-point dc-measurements using a flux-meter and on the other hand by extrapolating higher frequency measurements to dc magnetization using the statistical loss-separation theory (Jacobs et al., Magnetic material optimization for hybrid vehicle PMSM drives, in Inductica Conference, CD-Rom, Chicago/USA, 2009). Utilizing this material information, possibilities to identify the parameter of the IEM-Formula are analyzed. Along with this, the importance of excess losses in present-day non-grain oriented Fe-Si laminations is investigated. In conclusion, the calculated losses are compared to the measured losses. (C) 2013 American Institute of Physics.