4.5 Article

Potential use of V-channel Ge(220) monochromators in X-ray metrology and imaging

Journal

JOURNAL OF APPLIED CRYSTALLOGRAPHY
Volume 46, Issue -, Pages 945-952

Publisher

INT UNION CRYSTALLOGRAPHY
DOI: 10.1107/S0021889813006122

Keywords

-

Funding

  1. Project Research and Development Centre for Advanced X-ray Technologies (ITMS) [26220220170]
  2. Research & Development Operational Program
  3. European Regional Development Fund (ERDF) [0.5]
  4. Grant of Science and Technology Assistance Agency [APVV-0308-11]
  5. Scientific Grant Agency of the Ministry of Education of the Slovak Republic
  6. Slovak Academy of Sciences [VEGA-2/0153/10]
  7. CEITEC (Central European Institute of Technology) from the ERDF [CZ.1.05/1.1.00/02.0068]

Ask authors/readers for more resources

While channel-cut crystals, in which the diffracting surfaces in an asymmetric cut are kept parallel, can provide beam collimation and spectral beam shaping, they can in addition provide beam compression or expansion if the cut is V-shaped. The compression/expansion ratio depends in this case on the total asymmetry factor. If the Ge(220) diffraction planes and a total asymmetry factor in excess of 10 are used, the rocking curves of two diffractors will have a sufficient overlap only if the second diffractor is tuned slightly with respect to the first one. This study compares and analyses several ways of overcoming this mismatch, which is due to refraction, when the Cu K alpha(1) beam is compressed 21-fold in a V21 monochromator. A more than sixfold intensity increase was obtained if the matching was improved either by a compositional variation or by a thermal deformation. This provided an intensity gain compared with the use of a simple slit in a symmetrical channel-cut monochromator. The first attempt to overcome the mismatch by introducing different types of X-ray prisms for the required beam deflection is described as well. The performance of the V-shaped monochromators is demonstrated in two applications. A narrow collimated monochromatic beam obtained in the beam compressing mode was used for high-resolution grazing-incidence small-angle X-ray scattering measurements of a silicon sample with corrupted surface. In addition, a two-dimensional Bragg magnifier, based on two crossed V15 channel monochromators in beam expansion mode and tuned by means of unequal asymmetries, was successfully applied to high-resolution imaging of test structures in combination with a Medipix detector.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available