4.3 Article

Accuracy quantification of a deformable image registration tool applied in a clinical setting

Journal

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS
Volume 15, Issue 1, Pages 237-245

Publisher

WILEY
DOI: 10.1120/jacmp.v15i1.4564

Keywords

deformable image registration; expert-defined landmarks; target registration error; interobserver variations; adaptive radiation therapy

Ask authors/readers for more resources

The purpose of this study was to test the accuracy of a commercially available deformable image registration tool in a clinical situation. In addition, to demonstrate a method to evaluate the resulting transformation of such a tool to a reference defined by multiple experts. For 16 patients (seven head and neck, four thoracic, five abdominal), 30-50 anatomical landmarks were defined on recognizable spots of a planning CT and a corresponding fraction CT. A commercially available deformable image registration tool, Velocity AI, was used to align all fraction CTs with the respective planning CTs. The registration accuracy was quantified by means of the target registration error in respect to expert-defined landmarks, considering the interobserver variation of five observers. The interobserver uncertainty of the landmark definition in our data sets is found to be 1.2 +/- 1.1 mm. In general the deformable image registration tool decreases the extent of observable misalignments from 4-8 mm to 1-4 mm for nearly 50% of the landmarks (to 77% in sum). Only small differences are observed in the alignment quality of scans with different tumor location. Smallest residual deviations were achieved in scans of the head and neck region (79%, <= 4 mm) and the thoracic cases (79%, <= 4 mm), followed by the abdominal cases (59%, <= 4 mm). No difference is observed in the alignment quality of different tissue types (bony vs. soft tissue). The investigated commercially available deformable image registration tool is capable of reducing a mean target registration error to a level that is clinically acceptable for the evaluation of retreatment plans and replanning in case of gross tumor change during treatment. Yet, since the alignment quality needs to be improved further, the individual result of the deformable image registration tool has still to be judged by the physician prior to application.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available