A new analytical bias correction for in situ Sr isotope analysis of plagioclase crystals using laser-ablation multiple-collector inductively coupled plasma mass spectrometry

Journal

JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY
Volume 28, Issue 6, Pages 945-957

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/c3ja30329b

Keywords

-

Ask authors/readers for more resources

A new analytical protocol was developed for correcting baseline-induced biases during the analysis of Sr isotope ratios in plagioclase using excimer laser-ablation Aridus-dual-intake-system multiple-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS). Residual analytical biases of Sr-84/Sr-86 and Sr-87/Sr-86 were observed after applying on-peak background subtractions and mass-fractionation corrections using the conventional Sr-86/Sr-88 exponential internal normalization. The residual biases occurred only for samples analysed with LA and not for solution analyses using Aridus with the same instrumental setup. Based on observations from the ablation of NaCl and olivine crystals, we concluded that this was due to suppression and enhancement of the Kr baseline by loading of the LA sample aerosols and by the introduction of Kr from the samples, respectively. We also found that both the Sr-84/Sr-86 and Sr-87/Sr-86 isotope ratios were affected proportionally by the baseline biases of the LA analyses of an isotopically/compositionally homogeneous anorthite plagioclase (MkAn) from Miyakejima, Japan, and similar results were seen in theoretical calculations. Therefore, the bias correction for the target Sr-87/Sr-86 ratios was available using the shift in the simultaneously measured Sr-84/Sr-86 from the natural ratio. We then determined the correlation factors between Sr-84/Sr-86 and Sr-87/Sr-86 using numerical simulations and confirmed them by analysing MkAn, which closely reproduced the theoretical factors. By applying the new theoretical correction protocol, the accurate measurement of unknown plagioclase samples was possible without using any standard. This was confirmed by comparison with the results of micro-milling thermal ionization mass spectrometry (MM-TIMS) of the same plagioclase crystals with various compositions. The new correction technique improved reproducibility by a factor of four, providing a basis for an accurate Sr isotope analysis using LA-MC-ICP-MS.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available