4.7 Article

Unmodified manganese ferrite nanoparticles as a new sorbent for solid-phase extraction of trace metal-APDC complexes followed by inductively coupled plasma mass spectrometry analysis

Journal

JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY
Volume 27, Issue 10, Pages 1743-1752

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/c2ja30139c

Keywords

-

Funding

  1. National Science Fund of Bulgaria [DO 0270]
  2. EC [245588]
  3. Spanish Ministry of Science and Innovation [CTQ2008-06730-C02-01, CTQ2011-23968]

Ask authors/readers for more resources

The applicability of MnFe2O4 nanoparticles as a new sorbent for group pre-concentration of V, Co, Ni, Cu, Zn, As, Se, Cd and Pb was investigated and compared with that of magnetite nanoparticles. A solid-phase extraction (SPE) of target analytes based on sorption of their hydrophobic complexes with ammonium pyrrolidine dithiocarbamate (APDC) on the surface of unmodified nanoparticles (NPs) was optimized. Magnetic NPs with retained metal complexes were easily separated from the bulk solution by a permanent magnet applied for 5 min. Analyte restoration in the final solution was accomplished by heating with 0.5 mL of 7 mol L-1 nitric acid. The obtained solutions were suitable for continuous nebulization in ICP-MS. Spectral and non-spectral matrix effects for urine analysis (direct and after SPE) were studied and adequate calibration strategies are suggested. Under optimized conditions the magnetically assisted SPE procedure enables enrichment of target analytes by factors of between 7.4 and 10, with linear dynamic ranges of 1-100 mu g L-1 for V, Co, Ni, Cd, Pb and 101000 mu g L-1 for Zn, As, Se and method detection limits in the interval 0.01-0.7 mu g L-1. The relative standard deviations (RSD%, for 10 mu g L-1 V, Co, Ni, Cd, Pb and for 100 mu g L-1 Zn, As, Se, n = 6) were less than 5.5%. The accuracy of the method was evaluated by analysing urine certified reference material Seronorm (TM) Trace Elements Urine 201205 and obtained recoveries were in the range 85-109%. For correct determination of As and Se in urine, a preliminary microwave sample treatment with a mixture HNO3 + H2O2 was needed, but it led to a worsening of method detection limits. The developed method was successfully applied for analysis of human urine.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available