4.7 Article

Evaluation of different analytical strategies for the quantification of sulfur-containing biomolecules by HPLC-ICP-MS: Application to the characterisation of S-34-labelled yeast

Journal

JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY
Volume 25, Issue 7, Pages 989-997

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/b925366a

Keywords

-

Funding

  1. Ministry of Science and Innovation, Madrid, Spain [CTQ2006-05722]
  2. Education and Science Council of the Principado de Asturias [BP07-059]

Ask authors/readers for more resources

Different analytical strategies, such as Compound Independent Calibration (CIC), post-column Isotope Dilution Analysis (IDA) and post-column Isotope Pattern Deconvolution (IPD) were evaluated for the determination of sulfur-containing biomolecules. CIC graphs were obtained for the sulfur-containing compounds sulfate, cysteine, glutathione and methionine separated by isocratic HPLC using four different ICP-MS instruments. Instruments evaluated included two quadrupole based instruments (XSeries II and HP-4500), with and without a collision cell respectively, one single collector double focusing (Element 2) and one multicollector double focusing (Neptune). When isocratic HPLC separations were employed, CIC using sulfate standards could be applied for the determination of small peptides and amino acids in their native form. When gradient elution HPLC separations were performed, CIC was no longer suitable and enriched stable isotopes (S-33) were evaluated to compensate for gradient-derived changes in the sensitivity for sulfur in the ion source. It was observed that post-column IDA using S-33 was suitable for the absolute quantification of sulfate, cysteine, glutathione and methionine by HPLC-ICP-MS when gradient elution was performed. Unfortunately, traditional equations used for post-column IDA can no longer be applied when two different sulfur enriched isotopes are employed. In the characterisation of S-34-labelled yeast we will have three different sulfur isotope patterns: natural abundance sulfur impurities, S-34 used as labelling'' tracer and S-33 used as post-column quantification'' tracer. So, for the characterisation of S-34-labelled yeast we have developed a post-column IPD procedure that allowed us to obtain the pattern specific molar flow chromatograms'' and, hence, to discriminate between natural abundance'' and S-34-enriched'' sulfur species in the S-34-labelled yeast.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available