4.6 Article

Two-Year Outcomes After First- or Second-Generation Drug-Eluting or Bare-Metal Stent Implantation in All-Comer Patients Undergoing Percutaneous Coronary Intervention

Journal

JACC-CARDIOVASCULAR INTERVENTIONS
Volume 7, Issue 1, Pages 20-28

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2013.09.008

Keywords

all-comer randomized clinical trial; bare-metal stent(s); everolimus-eluting stent(s); paclitaxel-eluting stent(s); zotarolimus-eluting stent(s)

Ask authors/readers for more resources

Objectives This study sought to assess device-specific outcomes after implantation of bare-metal stents (BMS), zotarolimus-eluting Endeavor Sprint stents (ZES-S), paclitaxel-eluting stents (PES), or everolimus-eluting stents (EES) (Medtronic Cardiovascular, Santa Rosa, California) in all-comer patients undergoing percutaneous coronary intervention. Background Few studies have directly compared second-generation drug-eluting stents with each other or with BMS. Methods We randomized 2,013 patients to BMS, ZES-S, PES, or EES implantation. At 30 days, each stent group received up to 6 or 24 months of clopidogrel therapy. The key efficacy endpoint was the 2-year major adverse cardiac event (MACE) including any death, myocardial infarction, or target vessel revascularization, whereas the cumulative rate of definite or probable stent thrombosis (ST) was the key safety endpoint. Results Clinical follow-up at 2 years was complete for 99.7% of patients. The MACE rate was lowest in EES (19.2%; 95% confidence interval [CI]: 16.0 to 22.8), highest in BMS (32.1%; 95% CI: 28.1 to 36.3), and intermediate in PES (26.2%; 95% CI: 22.5 to 30.2) and ZES-S (27.8%; 95% CI: 24.1 to 31.9) groups (chi-square test 18.9, p 0.00029). The 2-year incidence of ST in the EES group (1%; 95% CI: 0.4 to 2.2) was similar to that in the ZES-S group (1.4%; 95% CI: 0.7 to 2.8), whereas it was lower compared with the PES (4.6%, 95% CI: 3.1 to 6.8) and BMS (3.6%; 95% CI: 2.4 to 5.6) groups (chi-square 16.9; p = 0.0001). Conclusions Our study shows that cumulative MACE rate, encompassing both safety and efficacy endpoints, was lowest for EES, highest for BMS, and intermediate for PES and ZES-S groups. EES outperformed BMS also with respect to the safety endpoints with regard to definite or probable and definite, probable, or possible ST. (PROlonging Dual antiplatelet treatment after Grading stent-induced Intimal hyperplasia studY [PRODIGY]; NCT00611286) (C) 2014 by the American College of Cardiology Foundation

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available