4.6 Article

Transvenous, Antegrade Melody Valve-in-Valve Implantation for Bioprosthetic Mitral and Tricuspid Valve Dysfunction A Case Series in Children and Adults

Journal

JACC-CARDIOVASCULAR INTERVENTIONS
Volume 6, Issue 6, Pages 598-605

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2013.02.010

Keywords

bioprosthetic valve; mitral stenosis; percutaneous valve; tricuspid stenosis; valve-in-valve

Ask authors/readers for more resources

Objectives The purpose of this study was to report the results of percutaneous valve-in-valve therapy using the Melody valve (Medtronic, Minneapolis, Minnesota) for patients with degenerated mitral and tricuspid bioprosthetic valves. Background Open surgery for replacement of degenerated bioprosthetic valves is associated with morbidity and mortality. Methods Nineteen patients (median age 65 years, range 10 to 88 years; 7 males) with degenerated mitral (n = 9) or tricuspid (n = 10) bioprosthetic valves underwent transvenous valve-in-valve implantation of the Melody valve. Results In the mitral patients, the mean Society of Thoracic Surgeons mortality score was 13.3 +/- 5.6%. All patients had a prosthetic valve mean diastolic inflow gradient >= 5 mm Hg. Moderate or worse regurgitation was present in 7 of 9 mitral and 7 of 10 tricuspid patients. Implantation of a Melody valve was successful in all. Among the mitral patients, mean diastolic gradient decreased from 12.3 +/- 4.6 mm Hg to 5.2 +/- 2 mm Hg (p < 0.01). Residual regurgitation was trivial to mild in 6, mild to moderate in 2, and moderate in 1 patient. Among the tricuspid patients, mean diastolic gradient decreased from 10.0 +/- 4.3 mm Hg to 5.6 +/- 2.5 mm Hg (p < 0.01). Residual regurgitation was trivial to mild in 9 and mild to moderate in 1 patient. New York Heart Association functional class improved in 17 of 19 patients (p < 0.01). No periprocedural deaths, myocardial infarctions, strokes, or valve embolizations occurred. Vascular access site complications occurred in 4 patients. Conclusions Percutaneous valve-in-valve implantation of the Melody valve in the mitral or tricuspid position for treatment of bioprosthetic valve dysfunction is feasible and can lead to significant symptomatic improvement in carefully selected high-risk patients. (c) 2013 by the American College of Cardiology Foundation

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available