4.6 Article

3-Year Clinical Outcomes in the Randomized SORT OUT III Superiority Trial Comparing Zotarolimus- and Sirolimus-Eluting Coronary Stents

Journal

JACC-CARDIOVASCULAR INTERVENTIONS
Volume 5, Issue 8, Pages 812-818

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2012.04.008

Keywords

coronary; drug-eluting; randomized clinical trial; sirolimus; stent; zotarolimus

Funding

  1. Cordis
  2. Medtronic
  3. Boston Scientific
  4. Abbott
  5. St. Jude Medical
  6. Johnson Johnson Cordis
  7. Terumo

Ask authors/readers for more resources

Objectives This study sought to examine the 3-year clinical outcomes in patients treated with the Endeavor (Medtronic, Santa Rosa, California) zotarolimus-eluting stent (ZES) or the Cypher (Cordis, Johnson & Johnson, Warren, New Jersey) sirolimus-eluting stent (SES) in routine clinical practice. Background The long-term clinical outcome in patients treated with ZES in comparison with SES is unclear. Methods The authors randomized 2,332 patients to ZES (n = 1,162) or SES (n = 1,170) implantation. Endpoints included major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction, or target vessel revascularization; the individual endpoints of MACE; and definite stent thrombosis. Results At 3-year follow-up, the MACE rate was higher in patients treated with ZES than in patients treated with SES (148 [12.9%] vs. 116 [10.1%]; hazard ratio [HR]: 1.33, 95% confidence interval [CI]: 1.04 to 1.69; p = 0.022). Target vessel revascularization was more frequent in the ZES group compared with the SES group (103 [9.1%] vs. 76 [6.7%]; HR: 1.40, 95% CI: 1.04 to 1.89; p = 0.025), whereas the occurrence of myocardial infarction (3.8% vs. 3.3%) and cardiac death (2.8% vs. 2.8%) did not differ significantly. Although the rate of definite stent thrombosis was similar at 3-year follow-up (1.1% vs. 1.4%), very late (12 to 36 months) definite stent thrombosis occurred in 0 (0%) patients in the ZES group versus 12 (1.1%) patients in the SES group (p = 0.0005). Conclusions Although the 3-year MACE rate is higher in patients treated with ZES versus SES, our data highlight a late safety problem concerning definite stent thrombosis with the use of SES. This finding underscores the importance of long-term follow-up in head-to-head comparisons of drug-eluting stents. (Randomized Clinical Comparison of the Endeavor and the Cypher Coronary Stents in Non-selected Angina Pectoris Patients [SORT OUT III]; NCT00660478) (J Am Coll Cardiol Intv 2012; 5: 812-8) (C) 2012 by the American College of Cardiology Foundation

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available