4.6 Article

Transcatheter Closure of Paravalvular Defects Using a Purpose-Specific Occluder

Journal

JACC-CARDIOVASCULAR INTERVENTIONS
Volume 3, Issue 7, Pages 759-765

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2010.04.013

Keywords

paravalvular regurgitation; transapical; Vascular Plug III; hemolysis

Ask authors/readers for more resources

Objectives This study sought to describe a method of paravalvular leak closure using a purpose-specific occlusion device. Background Transcatheter closure of paravalvular leaks has been hampered by technical challenges, the limitations of available imaging modalities, and the lack of closure devices specifically designed for this purpose. Methods Patients with severe symptomatic paravalvular regurgitation at high risk for repeat surgery underwent transcatheter leak closure. Both left ventricular puncture and retrograde transfemoral approaches were used with fluoroscopic and 3-dimensional transesophageal guidance. A purpose-specific occluder (Vascular Plug III, AGA Medical Corp., Plymouth, Minnesota) was used. Results Five patients with severe prosthetic mitral and aortic paravalvular leaks underwent attempted closure. Implantation of the device was successfully accomplished in all. In 1 patient, the plug interfered with closure of a mechanical valve leaflet and was removed and replaced with an alternate device. Complications included pericardial bleeding in 2 patients with a transapical approach. There was no procedural mortality. At a median follow-up of 191 days (interquartile range [IQR] 169 to 203 days) all patients were alive. New York Heart Association functional class fell from 4 (IQR 3 to 4) to 2 (IQR 2 to 3), hemoglobin rose from 89 g/l (IQR 87 to 108 g/l) to 115 g/l (IQR 104 to 118 g/l), creatinine fell from 109 mu mol/l (IQR 106 to 132 mu mol/l) to 89 mu mol/l (IQR 89 to 126 mu mol/l). Median echocardiographic follow-up at 58 days (IQR 56 to 70 days) reported residual regurgitation to be reduced from grade 4 to grade 2 (IQR 1.5 to 2.25). Conclusions Closure of mitral and aortic prosthetic paravalvular leaks with the Vascular Plug III using either a transapical (mitral) or a retrograde (aortic) approach appears promising. (J Am Coll Cardiol Intv 2010;3:759-65) (c) 2010 by the American College of Cardiology Foundation

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available