4.6 Editorial Material

Strut Coverage and Vessel Wall Response to Zotarolimus-Eluting and Bare-Metal Stents Implanted in Patients With ST-Segment Elevation Myocardial Infarction The OCTAMI (Optical Coherence Tomography in Acute Myocardial Infarction) Study

Journal

JACC-CARDIOVASCULAR INTERVENTIONS
Volume 3, Issue 6, Pages 680-687

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2010.04.005

Keywords

acute myocardial infarction; coronary artery disease; optical coherence tomography; stent coverage; zotarolimus-eluting stent

Ask authors/readers for more resources

Objectives Using optical coherence tomography, we assessed the proportion of uncovered struts at 6-month follow-up in zotarolimus-eluting stents (ZES), specifically Endeavor (Medtronic CardioVascular, Santa Rosa, California) stents, and identical bare-metal stents (BMS) implanted in patients with ST-segment elevation myocardial infarction (STEMI). Background Sirolimus- and paclitaxel-eluting stents implanted in STEMI have been associated with delayed healing and incomplete strut coverage. ZES are associated with a more complete and uniform strut coverage in stable patients, but whether this holds true also after STEMI is unknown. Methods Forty-four patients with STEMI who underwent primary PCI were randomized to ZES or BMS (3:1 randomization). Angiographic, intravascular ultrasound, and optical coherence tomography follow-up was conducted at 6 months and clinical follow-up at 1 year. All images were analyzed by an independent core laboratory that was blind to stent assignments. Results There were no differences between ZES and BMS in percentage of uncovered struts (median: 0.00% [interquartile range (IQR): 0.00% to 1.78%] vs. 1.98% [IQR: 0.21% to 7.33%], p = 0.13), maximum length of uncovered segments (0.00 [IQR: 0.00 to 1.19] mm vs. 1.38 [IQR: 0.65 to 3.30] mm, p = 0.10), percentage of malapposed struts (0.00% [IQR: 0.00% to 0.23%] vs. 0.15% [IQR: 0.00% to 5.81%], p = 0.16), and maximum length of malapposed segments (0.00 [IQR: 0.00 to 0.67] mm vs. 0.33 [IQR: 0.00 to 2.55] mm, p = 0.20). Neointimal response was similar between ZES and BMS (332 [IQR: 240 to 429] mu m vs. 186 [IQR: 136 to 348] mu m, p = 0.99) and evenly distributed. No late acquired malapposition was observed in both groups. There were no deaths, myocardial infarction, or stent thromboses at 1 year. Conclusions This optical coherence tomography study found no difference in strut coverage and similar vessel response to ZES, when compared with identical BMS, implanted during primary percutaneous coronary intervention in STEMI patients. (Six-Month Coverage and Vessel Wall Response of the Zotarolimus Drug-Eluting Stent Implanted in AMI Assessed by Optical Coherence Tomography [OCTAMI]; NCT00704561) (J Am Coll Cardiol Intv 2010;3:680-7) (C) 2010 by the American College of Cardiology Foundation

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available