4.6 Article

Impact of Post-Intervention Minimal Stent Area on 9-Month Follow-Up Patency of Paclitaxel-Eluting Stents An Integrated Intravascular Ultrasound Analysis From the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials

Journal

JACC-CARDIOVASCULAR INTERVENTIONS
Volume 2, Issue 12, Pages 1269-1275

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2009.10.005

Keywords

intravascular ultrasound; in-stent restenosis; paclitaxel-eluting stent; stent expansion

Funding

  1. Boston Scientific Corporation
  2. IVUS core lab

Ask authors/readers for more resources

Objectives We investigated the predictive value of the intravascular ultrasound (IVUS) measured post-intervention minimum stent area (MSA) on 9-month follow-up paclitaxel-eluting stent (PES) patency compared with bare-metal stents (BMS). Background Stent underexpansion is a strong predictor for restenosis after sirolimus-eluting stent implantation, but the implication of underexpansion in PES is still unknown. Methods From the combined TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent trials, 1,580 patients (PIES 1,098, BMS 482) in IVUS substudies were analyzed. The MSA that best predicted angiographic in-stent restenosis (ISR) (% diameter stenosis >= 50%) was determined. Results The post-intervention IVUS MSA was similar in PES and BMS (6.6 +/- 2.5 mm(2) vs. 6.7 +/- 2.3 mm(2), p = 0.92). At 9-month follow-up, ISR was lower in the PIES group versus the BMS group (10% vs. 31%, p < 0.0001). Using multivariable logistic regression analysis, post-intervention IVUS MSA was the independent predictor of subsequent ISR in both the PIES and BMS groups (p = 0.0002 for PIES and p = 0.0002 for BMS). The ability of the post-intervention IVUS MSA to predict ISR was further assessed using receiver operating characteristic analysis. The post-intervention IVUS MSA was found to be a faithful discriminator between patients with and without ISR in both PES (c = 0.6382) and BMS (c = 0.6373). Finally, the optimal thresholds of post-intervention IVUS MSA that best predicted stent patency at 9 months were 5.7 mm(2) for PES and 6.4 mm(2) for BMS. Conclusions Post-intervention MSA measured by IVUS can predict 9-month follow-up stent patency after both PES and BMS implantation. (Randomized Trial Evaluating Slow-Release Formulation TAXUS Paclitaxel-Eluting Coronary Stents to Treat De Novo Coronary Lesions; NCT00301522) (Direct Stenting of TAXUS Liberte-SR Stent for the Treatment of Patients With de Novo Coronary Artery Lesions; NCT00371423) (A Study of the TAXUS Liberte Stent for the Treatment of Long De Novo Coronary Artery Lesions; NCT00371475) (A Study of the TAXUS Liberte Stent for the Treatment of de Novo Coronary Artery Lesions in Small Vessels; NCT00371748) (J Am Coll Cardiol Intv 2009;2:1269-75) (C) 2009 by the American College of Cardiology Foundation

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available