4.6 Article

Efficacy of Computer-Aided Detection System and Thin-Slab Maximum Intensity Projection Technique in the Detection of Pulmonary Nodules in Patients With Resected Metastases

Journal

INVESTIGATIVE RADIOLOGY
Volume 44, Issue 2, Pages 105-113

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/RLI.0b013e318190fcfc

Keywords

multislice computed tomography; computer-aided detection; maximum intensity projection; pulmonary nodules; metastatectomy

Funding

  1. Seoul RBD program [10888]

Ask authors/readers for more resources

Objectives: To evaluate the efficacy of the computer-aided detection (CAD) system and thin-slab maximum intensity projection (MIP) technique in the detection of pulmonary nodules at multidetector computed tomography (CT) in patients who underwent metastatectomy. Materials and Methods: This retrospective study was approved by the institutional review board and patients' informed consent was waived. Forty-nine consecutive patients who underwent pulmonary metastatectomy were enrolled. Four chest radiologists analyzed preoperative 1-mm section CT images and recorded the locus of each nodule candidate. Afterward, they reevaluated the images once using CAD software and once with thin-slab MIP given the results of 1-mm section CT alone. The reference standard for nodule presence was established by a consensus panel and pathologic records for malignant nodules. Results: A total of 514 nodules were identified by a consensus panel. Of 212 nodules surgically removed, 121 nodules were malignant. The sensitivity of each observer in detecting malignant nodules with thin-section CT scans alone was 91%, 88%, 87%, and 86% for observers A- to D, respectively. With CAD, sensitivity increased significantly to 95%, 95%, 94%, and 95% (P<0.05 for observer B-D), and using MIP increased to 94%, 96%, 91%, and 92% (P<0.05 for observer B-D), respectively. There were no significant differences in sensitivity between CAD and MIP for the detection of malignant nodules. The average number of false-positive findings per patient was 0.8 with thin-section CT alone, 1.1 with CAD, and 1.4 with MIP. Conclusions: In candidates for metastatectomy, reading with the aid of either CAD or MIP significantly improved the detection of malignant nodules compared with using thin-section CT alone.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available