4.5 Review

Assessing crown fire potential in coniferous forests of western North America: a critique of current approaches and recent simulation studies

Journal

INTERNATIONAL JOURNAL OF WILDLAND FIRE
Volume 19, Issue 4, Pages 377-398

Publisher

CSIRO PUBLISHING
DOI: 10.1071/WF08132

Keywords

canopy base height; canopy bulk density; crown fire behaviour; crown fraction burned; crowning; Crowning Index; dead fuel moisture content; fire behaviour; fire behaviour modelling; fireline intensity; foliar moisture content; forest structure; rate of fire spread; Torching Index; wind speed

Categories

Ask authors/readers for more resources

To control and use wildland fires safely and effectively depends on creditable assessments of fire potential, including the propensity for crowning in conifer forests. Simulation studies that use certain fire modelling systems (i.e. NEXUS, FlamMap, FARSITE, FFE-FVS (Fire and Fuels Extension to the Forest Vegetation Simulator), Fuel Management Analyst (FMAPlus(R)), BehavePlus) based on separate implementations or direct integration of Rothermel's surface and crown rate of fire spread models with Van Wagner's crown fire transition and propagation models are shown to have a significant underprediction bias when used in assessing potential crown fire behaviour in conifer forests of western North America. The principal sources of this underprediction bias are shown to include: (i) incompatible model linkages; (ii) use of surface and crown fire rate of spread models that have an inherent underprediction bias; and (iii) reduction in crown fire rate of spread based on the use of unsubstantiated crown fraction burned functions. The use of uncalibrated custom fuel models to represent surface fuelbeds is a fourth potential source of bias. These sources are described and documented in detail based on comparisons with experimental fire and wildfire observations and on separate analyses of model components. The manner in which the two primary canopy fuel inputs influencing crown fire initiation (i.e. foliar moisture content and canopy base height) is handled in these simulation studies and the meaning of Scott and Reinhardt's two crown fire hazard indices are also critically examined.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available