4.6 Article

A Randomized Trial of External Stenting for Saphenous Vein Grafts in Coronary Artery Bypass Grafting

Journal

ANNALS OF THORACIC SURGERY
Volume 99, Issue 6, Pages 2039-2045

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.athoracsur.2015.01.060

Keywords

-

Funding

  1. Vascular Graft Solutions Ltd, Tel Aviv, Israel
  2. National Institute for Health Research [NF-SI-0514-10166] Funding Source: researchfish

Ask authors/readers for more resources

Background. External stents inhibit saphenous vein graft (SVG) intimal hyperplasia in animal studies. We investigated whether external stenting inhibits SVG diffuse intimal hyperplasia 1 year after coronary artery bypass graft surgery. Methods. Thirty patients with multivessel disease undergoing coronary artery bypass graft surgery were enrolled. In addition to an internal mammary artery graft, each patient received one external stent to a single SVG randomly allocated to either the right or left coronary territories; and one or more nonstented SVG served as the control. Graft patency was confirmed at the end of surgery in all patients. The primary endpoint was SVG intimal hyperplasia (mean area) assessed by intravascular ultrasonography at 1 year. Secondary endpoints were SVG failure, ectasia (>50% initial diameter), and overall uniformity as judged by Fitzgibbon classification. Results. One-year follow-up angiography was completed in 29 patients (96.6%). All internal mammary artery grafts were patent. Overall SVG failure rates did not differ significantly between the two groups (30% stented versus 28.2% nonstented SVG, p = 0.55). The SVG mean intimal hyperplasia area, assessed in 43 SVGs, was significantly reduced in the stented group (4.37 +/- 1.40 mm(2)) versus nonstented group (5.12 +/- 1.35 mm(2), p = 0.04). In addition, stented SVGs demonstrated marginally significant improvement in lumen uniformity (p = 0.08) and less ectasia (6.7% versus 28.2%, p = 0.05). There was some evidence that ligation of side branches with metallic clips increased SVG failure in the stented group. Conclusions. External stenting has the potential to improve SVG lumen uniformity and reduce diffuse intimal hyperplasia 1 year after coronary artery bypass graft surgery. (C) 2015 by The Society of Thoracic Surgeons

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available