4.7 Article

Network sensor calibration for retrieving accurate moment tensors of acoustic emissions

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijrmms.2013.04.004

Keywords

Acoustic emissions; Focal mechanisms; Fracturing; Moment tensors; Sensor calibration

Funding

  1. Grant Agency of the Czech Republic [P210/12/1491]
  2. European Community's FP7 Consortium Project AIM Advanced Industrial Microseismic Monitoring [230669]

Ask authors/readers for more resources

We apply a method for retrieving accurate moment tensors in the acoustic emission (AE) experiments based on the joint inversion of a family of AE events for their moment tensors and for the sensor amplifications including coupling effects between sensors and a specimen. The accuracy and efficiency of the method is tested on AEs recorded during three different temporal stages of a triaxial compression experiment on a cylindrical Bentheim sandstone specimen. The results show improved quality of the moment tensors indicated by significantly lower root-mean-square residuals between observed and predicted amplitudes. The approach is particularly suitable for detailed studies of the source parameters of AE events, to obtain accurate focal mechanisms and seismic moment tensors and for detecting fracturing regime of microcracks. (C) 2013 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available