4.7 Article

Effect of temperature uncertainty on polymer electrolyte fuel cell performance

Journal

INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
Volume 39, Issue 3, Pages 1439-1448

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijhydene.2013.10.156

Keywords

Polymer electrolyte fuel cell; Polarisation area; Temperature uncertainty; Monte Carlo sampling; Thermal imaging

Funding

  1. EPSRC [EP/G030995/1, EP/1037024/1, EP/J001007/1]
  2. STFC [ST/K00171X/1]
  3. Royal Academy of Engineering
  4. Engineering and Physical Sciences Research Council [EP/I037024/1, EP/J001007/1, EP/G060991/1, EP/G030995/1] Funding Source: researchfish
  5. Science and Technology Facilities Council [ST/K00171X/1] Funding Source: researchfish
  6. EPSRC [EP/G030995/1, EP/J001007/1, EP/I037024/1, EP/G060991/1] Funding Source: UKRI
  7. STFC [ST/K00171X/1] Funding Source: UKRI

Ask authors/readers for more resources

The temperature of operation is a key parameter in determining the performance and durability of a polymer electrolyte fuel cell (PEFC). Controlling temperature and understanding its distribution and dynamic response is vital for effective operation and design of better systems. The sensitivity to temperature means that uncertainty in this parameter leads to variable response and can mask other factors affecting performance. It is important to be able to determine the impact of temperature uncertainly and quantify how much PEFC operation is influenced under different operating conditions. Here, a simple lumped mathematical model is used to describe PEFC performance under temperature uncertainty. An analytical approach gives a measure of the sensitivity of performance to temperature at different nominal operating temperatures and electrical loadings. Whereas a statistical approach, using Monte Carlo stochastic sampling, provides a 'probability map' of PEFC polarisation behaviour. As such, a polarisation 'area' or 'band' is considered as opposed to a polarisation 'curve'. Results show that temperature variation has the greatest effect at higher currents and lower nominal operating temperatures. Thermal imaging of a commercial air-cooled stack is included to illustrate the temporal and spatial temperature variation experienced in real systems. Copyright (C) 2013, The Authors. Published by Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available