Journal
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Volume 51, Issue 19-20, Pages 4628-4636Publisher
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijheatmasstransfer.2008.01.027
Keywords
contact angle; wetting; hysteresis; liquid-gas interfaces; solid-liquid interfaces; laser methods
Categories
Funding
- Bialystok Technical University [S/WBIS/23/08]
Ask authors/readers for more resources
The experimental stand to measure the static contact angle and drop diameter is presented in the paper. The results of contact angle and diameter of the drops on aluminium, brass, copper and stainless steel with different roughness are added. The measurements were done for the increasing and decreasing drop volume. As it result the hysteresis of contact angle and magnitude of wetting surface was observed. It was noticed that aluminium and stainless steel lose their hydrophobic properties during the dropping procedure while copper and brass remain the hydrophilic or hydrophobic material. (c) 2008 Elsevier Ltd. All rights reserved.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended