4.3 Article

The gaps-in-noise test: Gap detection thresholds in normal-hearing young adults

Journal

INTERNATIONAL JOURNAL OF AUDIOLOGY
Volume 47, Issue 5, Pages 238-245

Publisher

TAYLOR & FRANCIS LTD
DOI: 10.1080/14992020801908244

Keywords

GIN; test; gap detection; temporal resolution; auditory perception; psychoacoustics

Ask authors/readers for more resources

The aim of this study was to establish parameters for the gaps-in-noise test in normal-hearing young adults. One hundred subjects (50 males and 50 females) received an audiological evaluation to rule out hearing loss and auditory processing disorder. The gaps-in-noise test was then conducted on all subjects. The mean gap detection threshold was 4.19 ms. A psychometric function by gap duration was constructed, revealing that the percentage of correct responses was less than or equal to 5% for a gap duration of 2 ms, 10-30% for a gap duration of 3 ms, 60-70% for a gap duration of 4 ms, and over 96% for gap durations of 5 ms or longer. The results suggest that the data obtained can be applied as reference values for future testing. In the subjects evaluated, the gaps-in-noise test proved to be consistent with low variability.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available