4.6 Article

Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography

Journal

INTENSIVE CARE MEDICINE
Volume 35, Issue 6, Pages 1132-1137

Publisher

SPRINGER
DOI: 10.1007/s00134-009-1447-y

Keywords

Electrical impedance tomography; Computed tomography; Acute lung injury; Acute respiratory distress syndrome; Lung recruitment; Positive end-expiratory pressure; Mechanical ventilation

Funding

  1. Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP)
  2. Sao Paulo State Research Support Foundation
  3. Financiadora de Estudos e Projetos (FINEP)

Ask authors/readers for more resources

To present a novel algorithm for estimating recruitable alveolar collapse and hyperdistension based on electrical impedance tomography (EIT) during a decremental positive end-expiratory pressure (PEEP) titration. Technical note with illustrative case reports. Respiratory intensive care unit. Patients with acute respiratory distress syndrome. Lung recruitment and PEEP titration maneuver. Simultaneous acquisition of EIT and X-ray computerized tomography (CT) data. We found good agreement (in terms of amount and spatial location) between the collapse estimated by EIT and CT for all levels of PEEP. The optimal PEEP values detected by EIT for patients 1 and 2 (keeping lung collapse < 10%) were 19 and 17 cmH(2)O, respectively. Although pointing to the same non-dependent lung regions, EIT estimates of hyperdistension represent the functional deterioration of lung units, instead of their anatomical changes, and could not be compared directly with static CT estimates for hyperinflation. We described an EIT-based method for estimating recruitable alveolar collapse at the bedside, pointing out its regional distribution. Additionally, we proposed a measure of lung hyperdistension based on regional lung mechanics.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available