4.4 Article Proceedings Paper

Automated surveillance for central line - Associated bloodstream infection in intensive care units

Journal

INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY
Volume 29, Issue 9, Pages 842-846

Publisher

CAMBRIDGE UNIV PRESS
DOI: 10.1086/590261

Keywords

-

Funding

  1. NEI NIH HHS [R01 EY002091] Funding Source: Medline
  2. NIMH NIH HHS [R01 MH060974] Funding Source: Medline

Ask authors/readers for more resources

Objective. To develop and evaluate computer algorithms with high negative predictive values that augment traditional surveillance for central line-associated bloodstream infection (CLABSI). Setting. Barnes-Jewish Hospital, a 1,250-bed tertiary care academic hospital in Saint Louis, Missouri. Methods. We evaluated all adult patients in intensive care units who had blood samples collected during the period from July 1, 2005, to June 30, 2006, that were positive for a recognized pathogen on culture. Each isolate recovered from culture was evaluated using the definitions for nosocomial CLABSI provided by the National Healthcare Safety Network of the Centers for Disease Control and Prevention. Using manual surveillance by infection prevention specialists as the gold standard, we assessed the ability of various combinations of dichotomous rules to determine whether an isolate was associated with a CLABSI. Sensitivity, specificity, and predictive values were calculated. Results. Infection prevention specialists identified 67 cases of CLABSI associated with 771 isolates recovered from blood samples. The algorithms excluded approximately 40%-62% of the isolates from consideration as possible causes of CLABSI. The simplest algorithm, with 2 dichotomous rules (ie, the collection of blood samples more than 48 hours after admission and the presence of a central venous catheter within 48 hours before collection of blood samples), had the highest negative predictive value (99.4%) and the lowest specificity (44.2%) for CLABSI. Augmentation of this algorithm with rules for common skin contaminants confirmed by another positive blood culture result yielded in a negative predictive value of 99.2% and a specificity of 68.0%. Conclusions. An automated approach to surveillance for CLABSI that is characterized by a high negative predictive value can accurately identify and exclude positive culture results not representing CLABSI from further manual surveillance.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available