4.2 Article

Adverse drug reaction profile of nanoparticle versus conventional formulation of paclitaxel: An observational study

Journal

INDIAN JOURNAL OF PHARMACOLOGY
Volume 43, Issue 2, Pages 126-130

Publisher

MEDKNOW PUBLICATIONS & MEDIA PVT LTD
DOI: 10.4103/0253-7613.77341

Keywords

Adverse drug reaction; nanoparticle; observational study; paclitaxel

Ask authors/readers for more resources

Objectives : Conventional polyethoxylated castor oil (PCO)-based paclitaxel is associated with major adverse drug reactions (ADRs). Nanoxel, a nanoparticle-based formulation, may improve its tolerability by removing the need for PCO vehicle, and also permit its use in a higher dose. We conducted intensive monitoring of the ADR profile of Nanoxel in comparison with conventional paclitaxel in a public tertiary care set-up. Materials and Methods : ADR data were collected from 10 patients receiving Nanoxel and 10 age-matched controls receiving conventional paclitaxel in this longitudinal observational study, conducted in a medical oncology ward over 18 months. Severity was graded as per US National Cancer Institute Common Terminology Criteria for Adverse Events. Results : The groups had comparable demography at baseline. The median disease duration and per cycle median dose of paclitaxel were greater in the Nanoxel arm. Total 119 ADRs were noted with Nanoxel and 123 with conventional paclitaxel. Of these, 25 (21.0, 95 CI 13.69-28.33) in the Nanoxel and 20 (16.2, 95 CI 9.74-22.78) in paclitaxel group were of grade 3/4 severity. Common events included myalgia, nausea, anemia, paresthesia, alopecia, diarrhea, and vomiting with Nanoxel, and paresthesia, anemia, myalgia, anorexia, alopecia, vomiting, diarrhea, stomatitis, and nausea with paclitaxel. Of the less common events (< 5), grade 2 or 3 arthralgia was seen exclusively with Nanoxel while motor neuropathy with muscular weakness was more frequent and severe with conventional paclitaxel. Hypersensitivity reactions were not encountered in either arm, although no antiallergy premedication was employed for Nanoxel. Conclusions : Despite its ADR profile being statistically comparable to conventional paclitaxel, this observational study suggests that Nanoxel tolerability could be better, considering that a significantly higher dose was employed. This hypothesis needs confirmation through an interventional study.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available