4.8 Article

Core Losses Under the DC Bias Condition Based on Steinmetz Parameters

Journal

IEEE TRANSACTIONS ON POWER ELECTRONICS
Volume 27, Issue 2, Pages 953-963

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TPEL.2011.2160971

Keywords

Core losses; dc bias; ferrite; Steinmetz

Ask authors/readers for more resources

The calculation of core losses in inductive components is difficult and has not yet been entirely solved. In particular, it is impossible to predict the influence of a dc premagnetization on the losses without extensive measurements. For this paper, different materials have been tested to gain information on how core losses are influenced by a premagnetization. Measurements on molypermalloy powder, silicon steel, nanocrystalline material and ferrite cores have been performed. The Steinmetz premagnetization graph (SPG) that shows the dependency of the Steinmetz parameters (a, beta, and k) on premagnetization is introduced. This permits the calculation of core losses under dc bias conditions. Such graphs are given for different materials and different operating temperatures. In addition, a detailed description of the test system is given, as high accuracy is crucial.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available