4.7 Article

Multimodal Registration and Data Fusion for Cardiac Resynchronization Therapy Optimization

Journal

IEEE TRANSACTIONS ON MEDICAL IMAGING
Volume 33, Issue 6, Pages 1363-1372

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TMI.2014.2311694

Keywords

Electrophysical imaging; heart; multi-modality fusion; registration; ultrasound; X-ray imaging and computed tomography

Funding

  1. French National Research Agency (ANR) [ANR CIC-IT 04 187-188-189-190]
  2. Labex CAMI [ANR-11-LABX-0004-01]
  3. Europe FEDER

Ask authors/readers for more resources

Cardiac resynchronization therapy (CRT) has been shown to improve cardiovascular function in specific patients suffering from heart failure. This procedure still needs to be optimized to overcome the high rate of implanted patients that do not respond to this therapy. We propose in this work a better characterization of the electro-mechanical (EM) coupling of each region of the left ventricle (LV) that could be useful to precise the best implantation site. A new descriptor is proposed with the extraction of local electro-mechanical delays. Their measurement is based on the fusion of anatomical, functional and electrical data acquired using computed tomography (CT), speckle tracking echocardiography (STE), and electro-anatomical mappings (EAM). We propose a workflow to place multimodal data in the same geometrical referential system and to extract local electro-mechanical descriptors. It implies the fusion of electrical and mechanical data on a 3D+ t anatomical model of the LV. It mainly consists in four steps: 1) the modeling of the endocardium using a dynamic surface estimated from CT images; 2) the semi-interactive registration of EAM data and CT images; 3) the automatic registration of STE data on the dynamic model, using a metric based on Fourier descriptors and dynamic time warping; 4) the temporal alignment between EAM and STE and the estimation of local electro-mechanical delays. The proposed process has been applied to real data corresponding to five patients undergoing CRT. Results show that local electro-mechanical delays provide meaningful information on the local characterization of the LV and may be useful for the optimal pacing site selection in CRT.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available