4.7 Article

Segmentation of the Optic Disc in 3-D OCT Scans of the Optic Nerve Head

Journal

IEEE TRANSACTIONS ON MEDICAL IMAGING
Volume 29, Issue 1, Pages 159-168

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TMI.2009.2031324

Keywords

Glaucoma; multiscale 3-D graph search; neuroretinal rim; optic disc; optic disc cup; optic nerve head (ONH); spectral-domain optical coherence tomography (OCT)

Funding

  1. National Institutes of Health [EY017066, EB004640]
  2. Carl Zeiss Meditec, Inc.
  3. Netherlands Organization for Health Related Research (ZonMW)
  4. Research to Prevent Blindness, NY
  5. Marlene S. and Leonard A. Hadley Glaucoma Research Fund
  6. Netherlands Organization for Scientific Research
  7. NATIONAL EYE INSTITUTE [R01EY017066, R01EY018853, R01EY019112] Funding Source: NIH RePORTER
  8. NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING [R01EB004640] Funding Source: NIH RePORTER

Ask authors/readers for more resources

Glaucoma is the second leading ocular disease causing blindness due to gradual damage to the optic nerve and resultant visual field loss. Segmentations of the optic disc cup and neuroretinal rim can provide important parameters for detecting and tracking this disease. The purpose of this study is to describe and evaluate a method that can automatically segment the optic disc cup and rim in spectral-domain 3-D OCT (SD-OCT) volumes. Four intraretinal surfaces were segmented using a fast multiscale 3-D graph search algorithm. After surface segmentation, the retina in each 3-D OCT scan was flattened to ensure a consistent optic nerve head shape. A set of 15 features, derived from the segmented intraretinal surfaces and voxel intensities in the SD-OCT volume, were used to train a classifier that can determine which A-scans in the OCT volume belong to the background, optic disc cup and rim. Finally, prior knowledge about the shapes of the cup and rim was incorporated into the system using a convex hull-based approach. Two glaucoma experts annotated the cup and rim area using planimetry, and the annotations of the first expert were used as the reference standard. A leave-one-subject-out experiment on 27 optic nerve head-centered OCT volumes (14 right eye scans and 13 left eye scans from 14 patients) was performed. Two different types of classification methods were compared, and experimental results showed that the best performing method had an unsigned error for the optic disc cup of 2.52 +/- 0.87 pixels (0.076 +/- 0.026 mm) and for the neuroretinal rim of 2.04 +/- 0.86 pixels (0.601 +/- 0.026 mm). The interobserver variability as indicated by the unsigned border positioning difference between the second expert observer and the reference standard was 2.52 +/- 1.03 pixels (0.076 +/- 0.031 mm) for the optic disc cup and 2.14 +/- 0.80 pixels (0.064 +/- 0.024 mm for the neuroretinal rim. The unsigned error of the best performing method was not significantly different (p > 0.2) from the interobserver variability.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available