Off-line PD Testing of Converter-fed Wire-wound Motors: When IEC TS 60034-18-41 May Fail?

Journal

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TDEI.2010.5595540

Keywords

Partial discharges; Converter; Testing; PWM; Square voltage; Turn insulation; Impulsive voltage

Ask authors/readers for more resources

This paper reports and discusses qualification and type test procedures for random wound motors as specified in IEC Technical Specification 60034-18-41. Since laboratory tests dealing with off-line partial discharges measurements followed by life tests showed that motors qualified as good can fail in very short times, an extensive investigation on the causes of such discrepancy and, in particular, on the differences existing between the stresses applied during off-line tests and in service is described. In addition, the results of partial discharge measurements performed on crossed pairs are presented, highlighting how the differences in the applied voltage waveform can influence the Repetitive Partial Discharge Inception Voltage. Suggestions to improve the off-line test procedure and related equipment are eventually discussed.