4.7 Article Proceedings Paper

A CMOS Electrochemical Impedance Spectroscopy (EIS) Biosensor Array

Journal

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TBCAS.2010.2081669

Keywords

Biosensor; DNA; electrochemical analysis; electrode; impedance spectroscopy; microarray; proteins

Ask authors/readers for more resources

In this paper, we present a fully integrated biosensor 10 x 10 array in a standard complementary metal-oxide semi-conducor process, which takes advantage of electrochemical impedance spectroscopy (EIS). We also show that this system is able to detect various biological analytes, such as DNA and proteins, in real time and without the need for molecular labels. In each pixel of this array, we implement a biocompatible Au electrode transducer and embedded sensor circuitry which takes advantage of the coherent detector to measure the impedance of the associated electrode-electrolyte interface. This chip is capable of concurrently measuring admittance values as small as 10(-8) Omega(-1) within the array with the detection dynamic range of more than 90 dB in the frequency range of 10 Hz-50 MHz.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available