4.7 Article

Control by Interconnection and Standard Passivity-Based Control of Port-Hamiltonian Systems

Journal

IEEE TRANSACTIONS ON AUTOMATIC CONTROL
Volume 53, Issue 11, Pages 2527-2542

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TAC.2008.2006930

Keywords

Hamiltonian systems; interconnection; nonlinear systems; passivity; passivity-based control (PBC); stabilization

Funding

  1. HYCON
  2. CONACYT (Mexico)

Ask authors/readers for more resources

The dynamics of many physical processes can be suitably described by Port-Hamiltonian (PH) models, where the importance of the energy function, the interconnection pattern and the dissipation of the system is underscored. To regulate the behavior of PH systems it is natural to adopt a Passivity-Based Control (PBC) perspective, where the control objectives are achieved shaping the energy function and adding dissipation. In this paper we consider the PBC techniques of Control by Interconnection (CbI) and Standard PBC. In CbI the controller is another PH system connected to the plant (through a power-preserving interconnection) to add tip their energy functions, while in Standard PBC energy shaping is achieved via static state feedback. In spite of the conceptual appeal of formulating the control problem as the interaction of dynamical systems, the current version of CbI imposes a severe restriction on the plant dissipation structure that stymies its practical application. On the other hand, Standard PBC, which is usually derived from a uninspiring and non-intuitive passive output generation viewpoint, is one of the most successful controller design techniques. The main objectives of this paper are: (1) To extend the CbI method to make it more widely applicable-in particular, to overcome the aforementioned dissipation obstacle. (2) To show that various popular variants of Standard PBC can be derived proceeding from a unified perspective. (3) To establish the connections between CbI and Standard PBC proving that the latter is obtained restricting the former to a suitable subset-providing a nice geometric interpretation to Standard PBC-and comparing the size of the set of PH plants for which they are applicable.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available