Recovering Reflectance of AQUA MODIS Band 6 Based on Within-Class Local Fitting

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSTARS.2010.2077620

Keywords

Aqua; MODIS band 6; recovering; within-class local fitting

Funding

  1. Major State Basic Research Development Program ( 973) of China [2009CB723905]
  2. National Natural Science Foundation [40801182, 40971220, 40901189]

Ask authors/readers for more resources

The Moderate Resolution Imaging Spectroradiometer (MODIS) aboard the Aqua satellite has been working well, except that 14 of the 20 detectors in Aqua MODIS band 6 (1.628-1.652 mu m) are ineffective. As a result, the periodic, along-scan strips in Aqua MODIS band 6 create problems in some high-level MODIS products. This paper demonstrates that MODIS bands 6 and 7 are highly correlated for each scene type. On this premise, we propose a within-class local fitting algorithm to recover missing reflectances of Aqua MODIS band 6. To test the efficacy of the proposed algorithm, experiments on real and simulated data are performed and the recovered images are evaluated qualitatively and quantitatively. The experimental results demonstrate that the proposed algorithm performs well.